Pneumococcal Capsular Polysaccharide (PCP) antibodies
Short Description : PCP IgG Antibodies


Blood
Test performed by: LabPLUS VIM Infectious Disease Serology


If specific antibody serotyping is required either as an initial test or a test-add, please refer to instructions under 'Pneumococcal antibody serotypes'

See Pneumococcal antibody serotypes


Specimen Collection
SST3.5 mL SST Serum (Preferred)
Plain4 mL Plain Serum
Microsample500 uL Microsample Serum
Reference Intervals
Units: mg/L
Age RangeEither Sex
All>= 16[1]

[1] Total IgG antibodies

Total IgG measuring range: 3.3 - 270 mg/L

Uncertainty of measurement: 20%


Turnaround Time:

Test performed on a batch basis (minimum of eleven specimens required).

Turnaround time 2 - 3 weeks.


Diagnostic Use and Interpretation

This assay is designed to measure IgG /IgG2 subclass antibody responses to pneumococcal vaccines incorporating 23 polysaccharides isolated form Streptococcus Pneumoniae .  These polysaccharides represent approximately 80% of the commonly encountered virulent serotypes.

The response in 30% of subjects to vaccination with S.pneumoniae is attributed to C-polysaccharide (CPS) antibodies and not too specific anti-PCP IgG/anti-PCP IgG2.  These CPS antibodies confer limited protection against pneumococcal infection, consequently CPS absorption has been incorporated in this assay.

Pneumococcal polysaccharide antigens elicit the production of mainly IgG/IgG2 antibodies, via a thymus independent response.  Patients with repeated bacterial infections should be investigated for immunodeficiency and thus inability to respond to specific polysaccharide antigens.

A patient's specific antibody response may be elevated by the serological determination of their IgG/IgG2 anti-PCP antibody levels pre- and post-vaccination using this quantitative enzyme immunoassay.

References

1.         Binding Site Bidazyme Anti-PCP IgG2 Enyme Immunoassay Kit package insert.

2.         Dr Rohan Ameratunga


Contact Information

For further information contact the laboratory, (09) 307 4949 ext 22103 or:
Associate Professor Rohan Ameratunga , Immunopathologist: Locator 93-5724,  

Dr Richard Steele , or  The LabPLUS Immunology Team



Last updated at 13:11:59 16/06/2022